<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>22260</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: No Plate float air detected
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF_Auto</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
not implimented in 1.20
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Not Applicable.
</text></DescriptionText>
</OperatorAction>
<Cause>
Plenum blower for plate float while exiting cassette was not detected
by the MCU genine (1) pressure sensor. Check offset (cass init), read
nulled value using cass. threshold is 4
</Cause>
<SeeAlso>
<UnnumberedList>
##Command cass
##Command cal
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:34:01 2008 PST
</Updated>
<Links>
</Links>
</Error>